The Honeywell HCM-710 Series is a cool mist humidifier designed for medium to large rooms, featuring a 1.5-gallon tank capacity, adjustable humidity control, quiet operation, wicking filter technology, easy-to-clean design, and an automatic shut-off function when empty. It helps relieve dryness in air for improved comfort. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. Specifications 4. Controls and Operation 5. Filling the Water Tank 6. Maintenance & Cleaning 7. Filter Replacement 8. Safety Features 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Water Tank, Base Unit with Motor, Wicking Filter, Humidistat Control Knob, Mist Outlet, Tank Handle, Power Cord.

FeatureDescription
Cool Mist TechnologyUses ultrasonic or evaporative technology to add moisture without heating water
Adjustable Humidity ControlDial to set desired humidity level (Low to High)
1.5-Gallon Tank CapacityProvides up to 24 hours of operation on low setting
Quiet OperationDesigned for bedroom or office use with minimal noise
Wicking FilterTraps minerals and impurities; requires periodic replacement
Automatic Shut-OffTurns off when tank is empty or removed
Easy-Fill TankWide opening for convenient filling and cleaning
Mist OutletAdjustable direction to direct mist flow
Indicator LightPower-on light; may blink when tank is empty
Carry HandleIntegrated handle for easy transport of tank

Installation & Setup

Unpack and inspect all parts. Place on a flat, stable surface away from walls and electronics.

  1. Remove tank from base: Lift tank by handle and separate from base unit.
  2. Install wicking filter: Insert filter into slot in base, ensuring it sits properly.
  3. Fill tank with water: Use clean, cool tap water. Do not use hot water or additives.
  4. Reassemble: Place tank back onto base, aligning properly.
  5. Plug into standard 120V AC outlet.
  6. Turn humidistat knob to desired setting (Low, Medium, High).

WARNING! Place on a water-resistant surface. Keep away from children and pets. Do not operate without water.

Specifications

Controls and Operation

Power is controlled by plugging into outlet. Operation is controlled via the humidistat knob on the front or side of the unit.

Humidistat Knob: Turn clockwise to increase mist output (Low → Medium → High). Turn fully counterclockwise to OFF.

Mist Outlet: Adjustable grille to direct mist away from walls or furniture.

Indicator Light: Glows blue/white when unit is powered and operating. May blink or change color when tank is empty.

Automatic Shut-Off: Activates when tank is empty or improperly seated. Unit will not operate until tank is refilled and correctly placed.

Filling the Water Tank

  1. Turn knob to OFF and unplug unit from outlet.
  2. Lift tank off base using handle.
  3. Carry tank to sink. Remove cap by turning counterclockwise.
  4. Fill with cool, clean tap water up to MAX fill line. Do not overfill.
  5. Replace cap securely and wipe any spilled water from tank exterior.
  6. Return tank to base, ensuring it sits level and engages properly.
  7. Plug in and turn knob to desired setting.

Tip: Use distilled or demineralized water to reduce white dust and extend filter life.

Maintenance & Cleaning

Regular cleaning prevents mold, mineral buildup, and ensures efficient operation.

Daily/Weekly: Wipe exterior with damp cloth. Check filter for mineral deposits.

Every 1-2 Weeks (or as needed):

  1. Unplug unit. Remove tank and empty any remaining water.
  2. Clean tank with mild soap and warm water. Rinse thoroughly.
  3. Clean base reservoir with vinegar solution (1 part white vinegar to 2 parts water) to dissolve mineral deposits. Scrub with soft brush.
  4. Rinse all parts with clean water and air dry completely before reassembly.

CAUTION! Never immerse motor unit in water. Do not use harsh chemicals, abrasives, or detergents.

Filter Replacement

Replace wicking filter every 1-3 months, depending on water hardness and usage.

  1. Unplug unit and remove tank.
  2. Remove old filter from slot in base. Discard properly.
  3. Insert new filter (Honeywell Part #HCM-710F) into slot. Ensure it is fully seated.
  4. Reassemble tank and base. Plug in and operate.

Note: A clogged or old filter reduces mist output and efficiency. Using distilled water can extend filter life.

Safety Features

Automatic Shut-Off: Turns off when water tank is empty or removed. Overheat Protection: Built-in thermal fuse prevents motor overheating. Tip-Over Protection: Some models may include shut-off if unit is tipped. Always operate on a flat, stable surface.

Regulatory Information

UL Listed: Meets UL 998 safety standards. FCC Part 15: Complies with limits for Class B digital devices. Manufactured for Honeywell International Inc. For support, visit www.honeywellhumidifiers.com or contact 1-800-332-1110. This product is covered by a limited 1-year warranty.

Troubleshooting

SymptomPossible CauseCorrective Action
No mist outputEmpty tank, clogged filter, incorrect assemblyFill tank; replace filter; ensure tank is seated properly on base.
Low mist outputMineral buildup, old filter, low settingClean unit; replace filter; turn knob to higher setting.
White dust around unitMinerals in waterUse distilled or demineralized water; replace filter.
Unit not turning onNo power, automatic shut-off engagedCheck outlet; ensure tank has water and is properly placed.
Water leakingOverfilled tank, loose cap, cracked tankDo not overfill; tighten cap; inspect for damage.
Unusual noiseMineral deposits on fan, loose partsClean unit; ensure all parts are secure.
Bad odorDirty tank or filter, stagnant waterClean tank and base thoroughly; replace filter; use fresh water daily.

Reset: Unplug for 10 minutes, then restart.