The Honeywell HCM-800 Series is a high-capacity cool mist humidifier designed for large rooms up to 800 sq. ft. It features a 1.5-gallon tank, adjustable humidity control, quiet operation, automatic shut-off, easy-to-clean design, and a wicking filter for demineralization. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Water tank, base unit with motor, wicking filter, control panel, humidity dial, and power cord.
| Feature | Description |
|---|---|
| Large Capacity Tank | 1.5-gallon tank for extended operation |
| Adjustable Humidity Control | Dial to set desired humidity level |
| Quiet Operation | Designed for minimal noise during use |
| Automatic Shut-Off | Turns off when tank is empty |
| Easy-to-Clean Design | Removable tank and base for simple cleaning |
| Wicking Filter | Demineralization filter for white dust reduction |
| Control Panel | Power button and humidity dial |
| Power Cord | Standard 120V AC power connection |
| Carry Handle | Integrated handle for easy transport |
| Filter Replacement Indicator | Light alerts when filter needs changing |
Unpack and inspect contents. Place on stable, level surface.
WARNING! Do not use with damaged cord or plug. Ensure unit is on a dry surface.
Prepare humidifier for initial use.
CAUTION! Use only clean, cool water. Do not add essential oils or chemicals.
Control Panel: Power switch, Humidity Control Dial, Filter Indicator Light.
Power Switch: Turns humidifier ON/OFF. Humidity Control Dial: Adjusts mist output and humidity level (Low to High). Filter Indicator Light: Illuminates when filter needs replacement (after approximately 30 days of use).
Operation Modes: Continuous run on selected setting. Automatic operation maintains set humidity level. Unit will automatically shut off when tank is empty.
Use only with proper electrical connection.
Tip: Place humidifier within 4 feet of outlet to avoid cord hazards.
For optimal performance and comfort.
WARNING! Never operate without water in tank. Do not move unit while in operation.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Unplug before cleaning. Never immerse base in water.
UL Listed: Meets safety standards for household use. FCC Part 15: Class B digital device; complies with interference limits. Copyright © Honeywell International Inc. For support, visit www.honeywellhumidifiers.com or contact 1-800-332-1110.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No mist output | Empty tank or clogged filter | Fill tank with water; replace filter if clogged. |
| Unit not turning on | Power issue or empty tank | Check power connection; ensure tank has water. |
| White dust in room | Hard water minerals | Use demineralization cartridge or distilled water. |
| Water leakage | Improper tank placement or damaged seal | Ensure tank is properly seated; check seals for damage. |
| Unusual noise | Motor issue or mineral buildup | Clean unit thoroughly; contact service if noise persists. |
| Filter indicator light on | Filter needs replacement | Replace wicking filter with new one. |
Reset: Unplug for 30 seconds, then restart.
Service: 1-800-332-1110; www.honeywellhumidifiers.com