The Honeywell Humidifier HE105 is a cool moisture console humidifier designed for medium to large rooms. It features a 1.5-gallon tank capacity, adjustable humidity control, a wicking filter system, a refill indicator light, quiet operation, and an auto shut-off function when the tank is empty. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Water Tank, Base Unit with Motor and Fan, Wick Filter, Humidistat Control Dial, Refill Indicator Light, Power Cord.
| Feature | Description |
|---|---|
| 1.5-Gallon Tank | Removable tank for easy filling |
| Adjustable Humidistat | Dial control to set desired humidity level |
| Wick Filter System | Evaporative filter that absorbs water; requires periodic replacement |
| Refill Indicator Light | Illuminates when the water tank is empty |
| Quiet Operation | Designed for low noise output |
| Auto Shut-Off | Turns off when tank is empty for safety |
| 360-Degree Mist Outlet | Distributes moisture evenly |
| Carry Handle | Integrated handle on tank for easy transport |
| Easy-Fill Opening | Wide tank opening for convenient refilling |
| Power Indicator Light | Shows when unit is powered on |
Unpack and inspect all contents. Place on a level, stable surface away from walls and electronics.
WARNING! Use only clean, cool water. Do not use hot water or add fragrances/oils to the water tank. Ensure unit is on a waterproof surface.
After installation, allow the wick to fully saturate with water for 15-20 minutes before operation.
CAUTION! Do not operate without the wick filter installed. Do not move the unit while it is filled with water.
Primary control is the humidistat dial on the front of the unit.
Dial Positions: OFF, LOW (1), MEDIUM (2-3), HIGH (4-5).
Indicator Lights:
Power Light (Green): Illuminates when unit is on.
Refill Light (Red): Illuminates when water tank is empty or very low.
Operation Tips: For best results, keep doors to the room closed. Ideal indoor humidity is between 40% and 60%. Use a hygrometer to monitor room humidity if desired. Turn dial to OFF when not in use or when refilling.
Regular cleaning prevents mold and mineral buildup. Unplug the unit before any maintenance.
CAUTION! Never immerse the motor housing or base electronics in water. Do not use abrasive cleaners or brushes.
The wick filter should be replaced every 1-2 months during the season, or when it appears heavily mineralized or dirty.
Tip: Using demineralization cartridges or distilled water can extend filter life.
Auto Shut-Off: The fan will automatically turn off when the water tank is empty, preventing damage to the motor.
Tip-Over Protection: Ensure the unit is placed on a stable surface. If tipped over, water may spill; unplug immediately.
Cool Mist Technology: Produces room-temperature mist, safe for use around children and pets.
Refill Indicator: Red light alerts you to add water, promoting efficient operation.
At the end of the humidification season, prepare the unit for storage.
CAUTION! Never store the unit with water in the tank or base, as this can lead to mold and mildew growth.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Honeywell International Inc. Honeywell and the Honeywell logo are registered trademarks of Honeywell International Inc. For support, replacement parts, or to locate a dealer, visit www.honeywellhumidifiers.com or contact customer service at 1-800-332-1110.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not turn on | Not plugged in / Power outage / Dial at OFF | Ensure plug is secure in outlet. Check household power. Turn dial from OFF position. |
| No mist output / Low mist | Empty tank / Dirty or old filter / Low humidity setting | Refill water tank. Replace wick filter. Turn humidistat to a higher setting. |
| Red Refill Light is on | Tank is empty or not seated properly | Refill tank. Remove and reseat tank firmly on base. |
| Water leaking from unit | Overfilled tank / Tank cap not tight / Crack in tank | Do not overfill. Ensure cap is tightened securely. Inspect tank for damage. |
| Unusual noise or odor | Dirty filter or base / Mineral buildup / Fan obstruction | Clean tank and base thoroughly. Replace filter. Ensure unit is on a level surface and nothing is blocking the fan. |
| White dust in room | Minerals in water being dispersed | Use distilled water or a demineralization cartridge. Clean the unit to remove existing scale. |
Reset: Unplug unit for 5 minutes, then plug back in. Ensure filter is installed correctly and tank is full.
Service: For issues not resolved above, contact Honeywell Customer Service at 1-800-332-1110 or visit www.honeywellhumidifiers.com. Do not attempt to repair the motor or electrical components yourself.