The Honeywell Humidifier HE150A-1005/U is a console-style humidifier designed to add moisture to dry air in medium to large rooms. It features a 1.5-gallon per day output, a 1.5-gallon water tank, a wicking filter system, an adjustable humidistat, three fan speeds (including an automatic setting), a refill indicator light, a directional mist outlet, and a programmable timer. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Operation Guide 7. Maintenance & Cleaning 8. Filter Replacement 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Main unit with water tank, Wick Filter, Humidistat Control, Fan Speed Selector, Timer, Refill Indicator Light, Directional Mist Outlet, and Power Cord.

FeatureDescription
Water Tank Capacity1.5 Gallons (5.7 Liters)
Output per DayUp to 1.5 Gallons (Medium to Large Rooms)
Wick Filter SystemEvaporative technology for clean, visible moisture
Adjustable HumidistatSet desired humidity level (30% to 60% RH)
Fan Speeds3 Settings: Low, High, and Auto
Programmable TimerSet unit to run for 2, 4, 8, or 12 hours
Refill Indicator LightIlluminates when water tank is empty
Directional Mist OutletAdjustable louvers to direct moisture flow
Power CordStandard 120V AC plug
Carry HandleIntegrated handle for easy tank transport

Installation & Setup

Unpack and inspect all contents. Place unit on a firm, level, waterproof surface indoors.

  1. Remove all packaging materials from the unit and water tank.
  2. Install the Wick Filter: Remove filter from plastic bag and insert into the filter frame inside the base unit.
  3. Fill the Water Tank: Carry tank to faucet, remove cap, fill with cool tap water, replace cap securely.
  4. Position the Tank: Place filled tank back onto the base unit, ensuring it seats properly.
  5. Plug into a 120V AC outlet.

WARNING! Place on a level surface away from direct heat sources and out of reach of children. Do not operate without the wick filter installed.

First-Time Use

After installation, power on the humidifier and configure initial settings.

  1. Power On: Press the POWER button. The unit will beep and the display will illuminate.
  2. Set Desired Humidity: Turn the HUMIDISTAT knob to your desired setting (e.g., 45%). The Auto fan setting will maintain this level.
  3. Select Fan Speed: Press the FAN button to cycle through Low, High, and Auto. Auto is recommended for first use.
  4. Set Timer (Optional): Press the TIMER button to select a shut-off duration (2, 4, 8, 12 hrs).
  5. Adjust Mist Direction: Use the louvers on the outlet to direct moisture flow.

CAUTION! Use only cool, clean tap water. Do not use hot water, additives, or essential oils. Ensure the tank cap is tight before placing on base.

Specifications

Controls and Settings

Access all functions via the control panel on the front of the unit.

Control Panel: POWER Button, HUMIDISTAT Knob, FAN Button (cycles speeds), TIMER Button, REFILL Indicator Light, Display (shows current humidity/settings).

Humidistat: Rotate knob to set target humidity level. The Auto fan mode will run the fan as needed to maintain this level.

Fan Speed: Low (quiet operation), High (maximum output), Auto (maintains set humidity automatically).

Timer: Program unit to turn off after 2, 4, 8, or 12 hours. Press TIMER repeatedly to cycle options.

Refill Indicator: Red light illuminates when the water tank is empty or nearly empty.

Operation Guide

For optimal performance and comfort.

  1. Daily Operation: Ensure tank is filled. Set desired humidity and fan speed. The unit will run until the tank is empty or the timer shuts it off.
  2. Refilling: When the REFILL light comes on, power off the unit, remove the tank, refill with cool water, and replace.
  3. Using Auto Mode: Set humidistat to desired level (e.g., 45%) and select Auto fan. The unit will automatically adjust fan speed to maintain that humidity.
  4. Using the Timer: Ideal for nighttime use. Set for desired hours; unit will beep and shut off automatically.
  5. Adjusting Mist Direction: Use the adjustable louvers to point moisture away from walls, furniture, or electronics.

Tip: Ideal indoor humidity is between 40% and 60%. Use a hygrometer to monitor room conditions.

Maintenance & Cleaning

Regular cleaning prevents mineral buildup and ensures efficient operation.

  1. Daily: Refill with fresh, cool water.
  2. Weekly: Clean the water tank and base unit.
  3. Monthly or as needed: Deep clean to remove scale; replace the wick filter (see Filter Replacement).

Cleaning Procedure:

  1. Unplug the unit.
  2. Remove and empty the water tank and base reservoir.
  3. Clean the tank and base with a soft cloth and a mixture of mild dish soap and warm water. Do not submerge the base electronics.
  4. Rinse thoroughly with clean water.
  5. Wipe the exterior with a dry, soft cloth.
  6. Allow all parts to air dry completely before reassembling.

CAUTION! Never use abrasive cleaners, bleach, or detergents not intended for plastic. Never immerse the base unit, motor, or electronics in water.

Filter Replacement

The wick filter should be replaced every 1-3 months, depending on water hardness and usage.

  1. Turn off and unplug the humidifier.
  2. Remove the water tank.
  3. Remove the old wick filter from the filter frame inside the base.
  4. Insert a new Honeywell replacement filter (Model HF-150) into the frame. Ensure it is seated properly and fully expanded.
  5. Reinstall the water tank and plug in the unit.

Note: Using a worn-out filter reduces moisture output and efficiency. Always use genuine Honeywell replacement filters.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Honeywell International Inc. Honeywell and the Honeywell logo are registered trademarks of Honeywell International Inc. For support, visit www.honeywellpluggedin.com or contact Honeywell Customer Care at 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not power onNot plugged in; outlet issueEnsure plug is firmly in a working outlet. Try a different outlet.
No mist/outputEmpty tank; dry filter; fan on LowRefill water tank. Ensure wick filter is wet. Increase fan speed.
Refill light is on but tank is fullFloat or sensor issueRemove and reseat tank. Ensure tank is positioned correctly on base.
White dust around unitMinerals in hard waterUse demineralization cartridge (optional) or distilled water. Clean unit more frequently.
Unusual noiseFan obstruction; loose partsTurn off and check for obstructions in fan area. Ensure all parts are secure.
Water leaking from baseOverfilled tank; damaged sealDo not overfill tank. Check tank cap and seals for cracks. Ensure unit is level.
Humidity not reaching set levelRoom too large/leaky; filter cloggedEnsure unit is sized for room. Replace wick filter. Close doors/windows.

Reset: Unplug unit for 60 seconds, then plug back in to reset electronic controls.

Service: For issues not resolved above, contact Honeywell Customer Care at 1-800-332-1110 or visit the support website. Do not attempt to repair the unit yourself.