Honeywell Humidifier HE22OA,B Manual

The Honeywell Humidifier HE22OA,B is a cool mist humidifier designed for medium to large rooms, featuring a 1-gallon tank capacity, adjustable humidity control, quiet operation, wick filter system, easy-to-fill tank, auto shut-off, and a refill indicator light. It helps alleviate dry air discomforts such as dry skin, irritated sinuses, and static electricity. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Operation 6. Maintenance & Cleaning 7. Replacing the Wick Filter 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Water Tank, Base Unit with Motor and Fan, Wick Filter, Humidity Control Dial, Power Switch, Refill Indicator Light.

FeatureDescription
1-Gallon Tank CapacityProvides up to 24 hours of operation on low setting
Adjustable Humidity ControlDial to set desired humidity level
Wick Filter SystemEvaporative filter that traps impurities; requires periodic replacement
Quiet OperationDesigned for bedroom or office use
Easy-Fill TankWide opening for convenient filling and cleaning
Auto Shut-OffTurns off when tank is empty or removed
Refill Indicator LightIlluminates when water level is low
Carry HandleIntegrated handle for easy transport
360-Degree Mist OutletAdjustable nozzle for directing mist flow
Power Cord StorageCompartment to wrap excess cord

Installation & Setup

Unpack and inspect all parts. Place on a stable, level, waterproof surface away from electronics and direct sunlight.

  1. Remove the water tank from the base unit.
  2. Install the wick filter: Remove from packaging, soak in cool water for 15-20 minutes, then insert into the base unit's filter frame.
  3. Fill the tank: Turn tank upside down, remove cap, fill with cool, clean tap or distilled water (do not use hot water or additives). Replace cap securely.
  4. Place tank onto base: Align tank with base and set down firmly. Ensure tank is seated properly to activate the valve.
  5. Plug into a 120V AC outlet.

WARNING! Always unplug the humidifier before moving, cleaning, or refilling. Do not operate without water or with an empty tank.

First-Time Use

After installation, follow these steps for initial operation.

  1. Power on: Press the power switch to the ON (I) position.
  2. Set humidity: Turn the humidity control dial to your desired setting (Low to High).
  3. Adjust mist direction: Rotate the 360-degree nozzle to direct mist away from walls, furniture, and electronics.
  4. Monitor operation: The unit will begin producing a cool mist. The refill light will illuminate when the tank is nearly empty.

CAUTION! Use only clean, cool water. Never add essential oils, fragrances, or other chemicals to the water tank, as this can damage the unit and void the warranty.

Specifications

Controls and Operation

Power Switch: Turns unit ON/OFF. Humidity Control Dial: Adjusts mist output (Low, Medium, High). Refill Indicator Light: Glows red when water level is low.

Daily Operation: Ensure tank is filled. Turn dial to desired setting. The wick filter will draw water from the base and the fan will blow air through it, releasing evaporated moisture into the air.

Auto Shut-Off: The unit will automatically power off when the tank is empty or if the tank is removed while the unit is running.

Tip: For optimal humidity (30-50%), use a hygrometer. Do not aim mist directly at people, walls, or electronic devices.

Maintenance & Cleaning

Regular cleaning prevents mold, mineral buildup, and ensures efficient operation. Clean every 1-2 weeks, or more often in hard water areas.

  1. Unplug the unit.
  2. Remove and empty the water tank.
  3. Clean tank: Fill with a mixture of 1 quart white vinegar and 1 gallon water. Swirl and let sit for 20 minutes. Scrub interior with a soft brush. Rinse thoroughly.
  4. Clean base: Wipe exterior with a damp cloth. Do not immerse base in water. Clean the water inlet valve and tray with a vinegar solution and soft cloth.
  5. Rinse all parts with clean water and air dry completely before reassembly.

CAUTION! Never use abrasive cleaners, bleach, or detergents. Do not allow water to enter the motor housing or electrical components.

Replacing the Wick Filter

The wick filter should be replaced every 1-3 months, or when it appears discolored, stiff, or has mineral deposits.

  1. Unplug the humidifier and remove the water tank.
  2. Remove the old wick filter from the base frame.
  3. Soak the new filter (Model HWF-110) in cool water for 15-20 minutes.
  4. Insert the saturated filter into the frame, ensuring it is seated properly.
  5. Reassemble the tank and base, then plug in the unit.

Note: Using a worn-out filter reduces mist output and efficiency. Use only genuine Honeywell replacement filters.

Storage Instructions

If not using for an extended period (e.g., summer months), prepare the unit for storage.

  1. Unplug the unit.
  2. Empty and thoroughly clean the tank and base as described in Section 7. Allow all parts to air dry completely.
  3. Remove and discard the used wick filter.
  4. Reassemble the unit without a filter, or store the new filter separately in its original packaging.
  5. Store in a cool, dry place in its original box if possible.

Tip: Do not store with water in the tank, as this can lead to mold and bacterial growth.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. Copyright © Honeywell International Inc. Honeywell and the Honeywell logo are registered trademarks. For customer support, replacement parts, or to locate a service center, visit www.honeywellhumidifiers.com or call 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
No mist / Low mist outputEmpty tank, clogged filter, low humidity settingRefill tank; replace wick filter; increase humidity control setting.
Unit not turning onNot plugged in, power switch off, auto shut-off engagedCheck power connection; ensure switch is ON; refill water tank.
Water leakingTank not seated properly, damaged tank or seal, overfilledRemove and reseat tank; inspect for cracks; ensure cap is tight; do not overfill.
Unusual noise or vibrationLoose parts, mineral buildup on fan, uneven surfaceEnsure tank is secure; clean base and fan (unplugged); place on level surface.
White dust in roomMinerals in hard water being dispersedUse distilled or demineralized water; clean unit and replace filter more frequently.
Refill light not illuminatingFaulty sensor, light bulb issueEnsure tank is empty; contact customer service if light fails when tank is dry.

Reset: Unplug unit for 5 minutes, then plug back in. Ensure tank is filled and filter is installed correctly.

Service: For issues not resolved above, contact Honeywell Customer Service at 1-800-332-1110 or visit www.honeywellhumidifiers.com. Do not attempt to repair the unit yourself.