The Honeywell Humidifier HE260 is a cool mist humidifier designed to add moisture to dry indoor air, helping to relieve dry skin, chapped lips, and other discomforts caused by low humidity. It features a 1-gallon tank capacity, adjustable mist control, automatic shut-off when empty, a wicking filter, and quiet operation. Ideal for medium-sized rooms. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Filling and Operation 7. Maintenance and Cleaning 8. Filter Replacement 9. Safety Precautions 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Water tank, base unit with motor, wicking filter, mist nozzle, control knob, and power cord.

FeatureDescription
1-Gallon TankRemovable tank for easy filling
Adjustable Mist ControlKnob to regulate mist output (Low/High)
Automatic Shut-OffTurns off when water level is low or tank is removed
Wicking FilterTraps minerals and impurities; requires periodic replacement
Quiet OperationDesigned for bedroom or office use
360° Mist NozzleAdjustable direction for optimal mist distribution
Water WindowVisible water level indicator
Carry HandleIntegrated handle for easy transport
Filter Change IndicatorLight or reminder to replace filter
Power Cord StorageCompartment to wrap excess cord

Installation

Unpack and inspect contents. Place on a flat, stable surface away from walls and electronics.

  1. Remove all packaging materials from tank and base.
  2. Install the wicking filter: Remove filter from package, soak in cool water for 15 minutes, then insert into filter tray in base.
  3. Fill the tank: Remove tank from base, unscrew cap, fill with cool tap water to MAX line, replace cap securely.
  4. Place tank back onto base, ensuring it sits firmly.
  5. Plug power cord into a 120V AC outlet.

WARNING! Place humidifier on a water-resistant surface. Do not use on carpet or near heat sources.

First-Time Setup

After installation, prepare for operation.

  1. Ensure humidifier is unplugged during initial setup.
  2. Soak filter as directed; improper soaking may reduce efficiency.
  3. Fill tank with cool water only (do not use hot water or additives).
  4. Place unit at least 12 inches from walls and furniture for proper mist dispersion.
  5. Plug in and turn mist control knob to desired setting (start with Low).

CAUTION! Never operate without water or filter installed. Use only clean, cool tap water.

Specifications

Controls and Settings

Simple control via knob on front or side of unit.

Mist Control Knob: Turn clockwise to increase mist output (Low to High). Turn counterclockwise to OFF position.

Indicator Lights: Power light (blue) indicates unit is on. Filter change light (red) illuminates when filter needs replacement.

Automatic Features: Shuts off when water tank is empty or removed. Nozzle adjusts 360° for directing mist.

Filling and Operation

Daily operation steps for optimal performance.

  1. Turn mist control knob to OFF and unplug unit.
  2. Lift tank off base and carry to sink.
  3. Unscrew tank cap, pour out any remaining water.
  4. Fill with cool tap water to MAX line; do not overfill.
  5. Replace cap tightly and return tank to base.
  6. Plug in unit, turn knob to desired setting (Low for quiet, High for maximum humidity).
  7. Adjust nozzle to direct mist away from walls and furniture.

Tip: Use distilled water if tap water is very hard to reduce mineral buildup.

Maintenance and Cleaning

Regular cleaning prevents mold and mineral deposits.

  1. Unplug unit and empty tank completely.
  2. Clean tank weekly with mild soap and water; rinse thoroughly.
  3. Wipe base exterior with damp cloth; never immerse base in water.
  4. Remove and rinse filter tray if mineral deposits are visible.
  5. Allow all parts to air dry completely before reassembly.
  6. Descale monthly with white vinegar solution (1 part vinegar to 3 parts water) if using hard water.

CAUTION! Do not use abrasive cleaners, bleach, or detergents. Never operate while wet.

Filter Replacement

Replace wicking filter every 1-3 months for optimal performance.

  1. Turn off and unplug humidifier.
  2. Remove water tank and set aside.
  3. Lift out old filter from filter tray and discard.
  4. Soak new filter in cool water for 15 minutes.
  5. Insert soaked filter into tray, ensuring it sits flat.
  6. Replace tank and reset filter indicator light if applicable (press and hold button for 5 seconds).

Note: Using a dirty filter reduces mist output and can cause odors.

Safety Precautions

Important safety guidelines to prevent injury or damage.

WARNING! Risk of electric shock if immersed. Do not use in bathroom or other high-moisture areas.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. UL listed for safety. Copyright © Honeywell International Inc. For support, visit www.honeywellhumidifiers.com or contact 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
No mist outputEmpty tank, clogged filter, knob offFill tank; replace filter; turn knob to Low or High.
Weak mistDirty filter, low water, mineral buildupReplace filter; refill tank; clean with vinegar solution.
Water leakageOverfilled tank, loose cap, cracked tankFill to MAX line only; tighten cap; inspect for damage.
Unusual noiseMineral deposits, loose partsDescale unit; ensure tank is seated properly.
Filter light onFilter needs replacementReplace wicking filter; reset indicator.
Unit not turning onNo power, automatic shut-off engagedCheck outlet; ensure tank has water and is properly placed.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-332-1110; www.honeywellhumidifiers.com