Honeywell Humidifier HE260A,B Manual

The Honeywell Humidifier HE260A,B is a cool mist humidifier designed to add comfortable moisture to dry air in medium to large rooms. It features a 1-gallon tank capacity, adjustable humidity control, a quiet operation mode, an easy-to-clean design, an automatic shut-off function when empty, a refill indicator light, and a wicking filter to trap impurities. Powered by 120V AC, 60Hz. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Operation 6. Maintenance & Cleaning 7. Replacing the Filter 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Water Tank, Base Unit with Motor, Control Knob, Mist Outlet, Filter Compartment, Refill Indicator Light.

FeatureDescription
1-Gallon Tank CapacityProvides long operation time between refills
Adjustable Humidity ControlKnob to set desired mist output level
Quiet OperationDesigned for low-noise performance
Easy-to-Clean DesignTank and base are simple to disassemble and clean
Automatic Shut-OffTurns off when tank is empty for safety
Refill Indicator LightIlluminates when the water tank is empty
Wicking FilterTraps minerals and impurities from the water
360° Mist OutletAdjustable nozzle for directing mist flow
Carrying HandleIntegrated handle for easy tank transport
Power Cord StorageCompartment to wrap excess cord neatly

Installation & Setup

Unpack and inspect all contents. Place on a firm, flat, level surface away from walls and electronics.

  1. Remove all packaging materials from the tank and base.
  2. Install the wicking filter: Remove filter from package, insert into the filter compartment in the base.
  3. Fill the tank: Carry tank to sink, remove cap, fill with cool tap water up to the fill line. Replace cap securely.
  4. Assemble: Place the filled water tank onto the base unit, aligning properly.
  5. Plug into a standard 120V AC electrical outlet.

WARNING! Use only cool tap or distilled water. Do not use hot water, additives, or oils. Ensure unit is on a stable, waterproof surface.

First-Time Use

After installation, follow these steps to begin operation.

  1. Power: Ensure unit is plugged in.
  2. Adjust Output: Turn the control knob to the desired setting (Low, Medium, High).
  3. Direct Mist: Adjust the 360° mist outlet to direct moisture away from walls and furniture.
  4. Monitor: The refill light will illuminate when the tank is empty. Refill promptly.
  5. For optimal humidity: Place unit centrally in the room, at least 12 inches from walls.

CAUTION! Never operate the unit without water or without the filter properly installed. Do not block the mist outlet.

Specifications

Controls and Operation

Primary control is the rotary knob on the base unit.

Control Knob: - **OFF:** Turns the humidifier off. - **LOW (I):** Minimal mist output for quiet, overnight use. - **MEDIUM (II):** Moderate mist output for average daily use. - **HIGH (III):** Maximum mist output for quickly raising room humidity.

Indicator Light:** A red light on the control panel illuminates when the water tank is empty, reminding you to refill.

Automatic Shut-Off:** The unit will automatically power off when the tank is empty to protect the motor.

Maintenance & Cleaning

Regular cleaning prevents mold and mineral buildup. Clean every 1-2 weeks during use.

  1. Unplug the unit from the electrical outlet.
  2. Empty any remaining water from the tank and base.
  3. Clean Tank: Fill tank with a mixture of 1 teaspoon of white vinegar and 1 gallon of water. Swirl and let sit for 20 minutes. Scrub interior with a soft brush, rinse thoroughly with clean water.
  4. Clean Base: Wipe the base reservoir and all surfaces with a soft cloth dampened with the vinegar solution. Do not submerge the base in water. Rinse cloth and wipe clean.
  5. Dry: Allow all parts to air dry completely before reassembling and storing or reusing.

CAUTION! Never use harsh chemicals, detergents, or abrasives. Do not immerse the motorized base in water or let water enter the control area.

Replacing the Filter

The wicking filter should be replaced every 1-2 months, or more often if using hard water or running continuously.

  1. Unplug the unit and remove the water tank.
  2. Open the filter compartment cover on the base.
  3. Remove the old filter and discard it.
  4. Insert a new Honeywell replacement filter (Model HF-260) into the compartment. Ensure it is seated flat.
  5. Close the filter compartment cover.
  6. Reassemble the tank and base, then plug in the unit.

Note: Using a worn-out filter reduces performance and mist output. Always use genuine Honeywell replacement filters.

Storage Instructions

When not using the humidifier for an extended period (e.g., summer months):

  1. Unplug the unit.
  2. Empty and thoroughly clean the tank and base as described in the cleaning section.
  3. Remove and discard the old filter. Do not store the unit with a used, wet filter inside.
  4. Allow all parts to dry completely for at least 24 hours.
  5. Reassemble the dry unit or store parts separately.
  6. Pack in original box or cover with a plastic bag to keep dust-free. Store in a cool, dry place.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Honeywell International Inc. Honeywell and the Honeywell logo are registered trademarks of Honeywell International Inc. For support, replacement parts, or to locate a retailer, visit www.honeywellpluggedin.com or contact Consumer Support at 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
No mist outputEmpty tank, clogged filter, knob in OFFRefill tank with water. Replace filter. Turn knob to desired setting.
Red indicator light is onWater tank is emptyUnplug unit, remove tank, refill with water, and replace.
Unit is noisyLow water level, mineral buildupRefill tank. Clean tank and base per instructions. Ensure unit is on a level surface.
Water leakageTank cap not tight, overfilled tank, cracked tankEnsure cap is securely tightened. Do not fill above "MAX" line. Inspect tank for cracks and replace if damaged.
White dust on surfacesMinerals from hard waterUse distilled water or replace demineralization filter more frequently.
Reduced mist outputClogged or old filterReplace with a new Honeywell HF-260 filter.
Unit won't turn onNot plugged in, no power at outletCheck that power cord is plugged into unit and wall outlet. Test outlet with another device.

Service: This unit contains no user-serviceable parts. Do not attempt to disassemble or repair the motor base. For service, contact Honeywell Consumer Support.

Support: 1-800-332-1110; www.honeywellpluggedin.com