The Honeywell HEV320B is a 2-gallon cool mist humidifier designed for medium to large rooms up to 500 sq. ft. It features a wicking filter system, three mist output settings, a refill indicator light, a 24-hour timer, an essential oil tray, and quiet operation. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Operation Guide 7. Maintenance & Cleaning 8. Filter Replacement 9. Safety Information 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: 2-gallon water tank, wicking filter, control panel with digital display, mist nozzle, essential oil tray, and power adapter.

FeatureDescription
Water Tank Capacity2 gallons (7.6 liters)
Room CoverageUp to 500 square feet
Mist Output SettingsLow, Medium, High (adjustable)
Run TimeUp to 24 hours on low setting
Digital ControlsTouch button panel with LED display
Timer Function1-12 hour programmable timer
Refill IndicatorLED light alerts when tank is empty
Essential Oil TrayOptional aroma diffusion capability
Quiet OperationDesigned for bedroom or office use
Auto Shut-offTurns off when tank is empty or removed

Installation & Setup

Unpack and inspect all components. Place on a flat, stable surface away from walls and electronics.

  1. Remove all packaging materials from humidifier and filter.
  2. Install the wicking filter: Remove from package, soak in cool water for 15 minutes, then insert into filter frame.
  3. Fill the water tank: Remove tank from base, flip upside down, unscrew cap, fill with cool tap water, replace cap securely.
  4. Place tank on base: Ensure tank is properly seated and aligned.
  5. Plug power cord into a 120V AC outlet.

WARNING! Place humidifier on a waterproof mat or towel. Keep away from children and pets. Do not use with extension cords.

First-Time Use

Power on the humidifier; follow these initial steps.

  1. Press POWER button to turn on; default setting is LOW mist.
  2. Adjust mist output: Press MIST button to cycle through Low, Medium, High settings.
  3. Set timer: Press TIMER button to set auto shut-off (1-12 hours).
  4. Add essential oils (optional): Place a few drops in the designated tray only.
  5. Monitor humidity: Ideal room humidity is 40-60%.

CAUTION! Use only clean, cool tap water. Do not use hot water or add oils directly to water tank.

Specifications

Controls and Settings

Control Panel Features: POWER, MIST (Low/Med/High), TIMER (1-12 hrs), FILTER RESET indicator, REFILL indicator.

Display Icons: Power indicator, Mist level (1-3 dots), Timer countdown, Refill alert (flashing water drop), Filter replacement reminder (wrench icon).

Settings Overview: Mist output adjustable for desired humidity level. Timer can be set for automatic shut-off. Filter Reset: Hold FILTER button for 3 seconds after replacing filter to reset indicator. Essential Oil Tray: Located on side; use only 2-3 drops maximum.

Operation Guide

Daily Operation: Ensure tank is filled, filter is moist, and unit is on stable surface.

  1. Fill tank daily with cool tap water; do not overfill.
  2. Select mist setting based on room size and humidity needs.
  3. Use timer for overnight operation or energy saving.
  4. Monitor refill indicator; refill when light turns on.
  5. Clean essential oil tray regularly if used.

Tip: Place humidifier at least 12 inches from walls and furniture for optimal mist distribution.

Maintenance & Cleaning

Regular cleaning prevents mold and mineral buildup.

  1. Unplug unit before cleaning.
  2. Empty and rinse tank daily.
  3. Weekly cleaning: Use mild soap and water for tank and base; never immerse base in water.
  4. Monthly deep clean: Use white vinegar solution (1 part vinegar to 3 parts water) to descale.
  5. Dry all parts thoroughly before reassembly.

WARNING! Do not use bleach, abrasive cleaners, or detergents. Never immerse motor or electronics in water.

Filter Replacement

Replace wicking filter every 1-3 months depending on water hardness and usage.

  1. Turn off and unplug humidifier.
  2. Remove water tank and old filter from frame.
  3. Soak new filter (HEV320WF) in cool water for 15 minutes.
  4. Insert filter into frame, ensuring proper alignment.
  5. Reset filter indicator: Hold FILTER button for 3 seconds until light turns off.

Note: Using demineralization cartridges or distilled water can extend filter life.

Safety Information

Important safety precautions for proper operation.

CAUTION! Risk of electric shock if immersed. Do not attempt to repair unit yourself.

Regulatory Information

FCC Compliance: This device complies with Part 15 of FCC Rules. UL Listed: Meets UL safety standards. Copyright © Honeywell International Inc. For support, visit www.honeywellhumidifiers.com or contact 1-800-332-1110. Model HEV320B manufactured for residential use only.

Troubleshooting

SymptomPossible CauseCorrective Action
No mist outputEmpty tank, clogged filterRefill water tank; clean or replace filter.
Low mist outputMineral buildup, dry filterDescale unit; ensure filter is properly soaked.
Unit not turning onNo power, safety lockCheck power outlet; ensure tank is properly seated.
Water leakageLoose cap, overfilled tankTighten tank cap; do not fill above MAX line.
Unusual noiseDebris in fan, loose partsClean fan area; ensure all components are secure.
Filter light onFilter needs replacementReplace filter and reset indicator.
White dustHard water mineralsUse demineralization cartridge or distilled water.

Reset: Unplug for 60 seconds to reset electronic controls.

Service: 1-800-332-1110; www.honeywellhumidifiers.com