The Honeywell Humidifier REFLECTION HUL900BC is a cool mist humidifier designed to add moisture to dry air in rooms up to 500 square feet. It features a 1.5-gallon tank capacity, a wicking filter system, a digital humidistat with automatic shut-off, three fan speeds, a refill indicator, and a night light function. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Water Tank, Base Unit with Motor, Wick Filter, Digital Control Panel, Humidistat Sensor, Night Light, and Power Adapter.
| Feature | Description |
|---|---|
| Digital Humidistat | Automatically maintains desired humidity level and shuts off when reached |
| 1.5-Gallon Tank | Large capacity for up to 24 hours of operation on low setting |
| Three Fan Speeds | Low, Medium, High for adjustable mist output |
| Wick Filter System | Traps minerals and impurities; requires periodic replacement |
| Refill Indicator | LED light alerts when tank is empty |
| Night Light | Soft blue illumination; can be turned on/off |
| Automatic Shut-Off | Turns off when desired humidity is reached or tank is empty |
| Easy-Fill Tank | Wide opening for convenient refilling |
| Carry Handle | Integrated handle for easy transport |
| Quiet Operation | Designed for bedroom or office use |
Unpack and inspect all contents. Place on a flat, stable, level surface away from walls and electronics.
WARNING! Use only the provided power adapter. Do not operate with damaged cord or plug. Keep away from children.
Power on the unit; the digital display will illuminate.
CAUTION! Always place on a water-resistant surface. Do not block mist outlet.
Access all functions via the digital control panel on the front of the base unit.
Control Panel: POWER Button, HUMIDITY Up/Down Buttons, SPEED Button, LIGHT Button, Digital Display (shows current humidity and settings).
Display Icons: Current Room Humidity %, Desired Humidity Setting, Fan Speed Indicator (1,2,3), Refill Indicator (drops icon), Night Light Indicator.
Settings: Desired Humidity (35%-65%), Fan Speed (adjusts mist output and noise level), Night Light (On/Off). The unit will run until the desired humidity is reached, then enter standby mode.
For daily operation, ensure the tank is filled and the filter is in place.
Tip: Ideal indoor humidity is between 40% and 50%. Use the humidistat to maintain this range.
Regular cleaning prevents mold and mineral buildup. Clean every 1-2 weeks during use.
WARNING! Never use bleach, harsh chemicals, or abrasive cleaners. Do not put base unit in dishwasher.
The wick filter should be replaced every 1-2 months, or when visibly coated with minerals or discolored.
Note: Using the humidifier without a filter or with a clogged filter can reduce performance and damage the unit.
When not in use for an extended period, prepare the unit for storage.
CAUTION! Never store with water inside. This can lead to mold, mildew, and damage.
FCC Compliance: This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Honeywell International Inc. Honeywell and Reflection are trademarks of Honeywell International Inc. For support, visit www.honeywellhumidifiers.com or contact Honeywell Customer Care at 1-800-332-1110.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not power on | No power / Loose plug | Ensure unit is plugged in securely. Check outlet with another device. |
| No mist output | Empty tank / Clogged filter | Refill water tank. Replace the wick filter if old or clogged. |
| Weak mist output | Low fan speed / Dirty filter | Increase fan speed. Clean or replace the wick filter. |
| Water leakage | Tank cap not tight / Cracked tank | Ensure tank cap is securely tightened. Inspect tank for cracks. |
| Unusual noise | Dry filter / Loose parts | Ensure filter is wet. Check that tank is seated properly on base. |
| Display not working | Power issue | Unplug and replug the unit. If problem persists, contact support. |
| Bad odor from mist | Dirty tank or filter | Clean the tank and base thoroughly. Replace the wick filter. |
Reset: Unplug the unit for 60 seconds, then plug back in to reset the electronic controls.
Service: For repairs, contact authorized service center. Do not attempt to disassemble the unit.
Support: 1-800-332-1110; www.honeywellhumidifiers.com