Honeywell Humidifier REFLECTION HUL900BC Manual

The Honeywell Humidifier REFLECTION HUL900BC is a cool mist humidifier designed to add moisture to dry air in rooms up to 500 square feet. It features a 1.5-gallon tank capacity, a wicking filter system, a digital humidistat with automatic shut-off, three fan speeds, a refill indicator, and a night light function. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Operation Guide 7. Maintenance & Cleaning 8. Filter Replacement 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Water Tank, Base Unit with Motor, Wick Filter, Digital Control Panel, Humidistat Sensor, Night Light, and Power Adapter.

FeatureDescription
Digital HumidistatAutomatically maintains desired humidity level and shuts off when reached
1.5-Gallon TankLarge capacity for up to 24 hours of operation on low setting
Three Fan SpeedsLow, Medium, High for adjustable mist output
Wick Filter SystemTraps minerals and impurities; requires periodic replacement
Refill IndicatorLED light alerts when tank is empty
Night LightSoft blue illumination; can be turned on/off
Automatic Shut-OffTurns off when desired humidity is reached or tank is empty
Easy-Fill TankWide opening for convenient refilling
Carry HandleIntegrated handle for easy transport
Quiet OperationDesigned for bedroom or office use

Installation & Setup

Unpack and inspect all contents. Place on a flat, stable, level surface away from walls and electronics.

  1. Remove tank from base and unscrew cap.
  2. Fill tank with cool, clean tap water. Do not use hot water or additives.
  3. Replace cap securely and wipe any spills.
  4. Place tank back onto base, ensuring it sits evenly.
  5. Insert the wick filter into the base slot, ensuring it is fully seated.
  6. Plug power adapter into base unit and then into a standard 120V AC outlet.

WARNING! Use only the provided power adapter. Do not operate with damaged cord or plug. Keep away from children.

First-Time Use

Power on the unit; the digital display will illuminate.

  1. Set desired humidity: Press the HUMIDITY button to cycle between 35% and 65% RH.
  2. Select fan speed: Press the SPEED button to choose Low, Medium, or High.
  3. Enable night light: Press the LIGHT button to turn the blue night light On or Off.
  4. The humidistat will automatically monitor room humidity and adjust operation.
  5. The REFILL indicator will light when the tank is empty.

CAUTION! Always place on a water-resistant surface. Do not block mist outlet.

Specifications

Controls and Settings

Access all functions via the digital control panel on the front of the base unit.

Control Panel: POWER Button, HUMIDITY Up/Down Buttons, SPEED Button, LIGHT Button, Digital Display (shows current humidity and settings).

Display Icons: Current Room Humidity %, Desired Humidity Setting, Fan Speed Indicator (1,2,3), Refill Indicator (drops icon), Night Light Indicator.

Settings: Desired Humidity (35%-65%), Fan Speed (adjusts mist output and noise level), Night Light (On/Off). The unit will run until the desired humidity is reached, then enter standby mode.

Operation Guide

For daily operation, ensure the tank is filled and the filter is in place.

  1. Press POWER to turn the unit on. The display will show current room humidity.
  2. Press HUMIDITY to set your target humidity level.
  3. Press SPEED to select mist output. Low for quiet night operation, High for rapid humidification.
  4. When the REFILL light turns on, unplug the unit, remove the tank, and refill with water.
  5. To turn off, press and hold the POWER button for 3 seconds, or unplug from the outlet.

Tip: Ideal indoor humidity is between 40% and 50%. Use the humidistat to maintain this range.

Maintenance & Cleaning

Regular cleaning prevents mold and mineral buildup. Clean every 1-2 weeks during use.

  1. Unplug the unit and remove the water tank and wick filter.
  2. Empty any remaining water from the base reservoir.
  3. Clean the tank and base with a mixture of mild dish soap and warm water. Use a soft brush for the tank interior.
  4. Rinse all parts thoroughly with clean water.
  5. Wipe the exterior with a soft, damp cloth. Do not immerse the base unit in water.
  6. Allow all parts to air dry completely before reassembling.
  7. For disinfecting, use a solution of 1 teaspoon of white vinegar per gallon of water. Rinse well.

WARNING! Never use bleach, harsh chemicals, or abrasive cleaners. Do not put base unit in dishwasher.

Filter Replacement

The wick filter should be replaced every 1-2 months, or when visibly coated with minerals or discolored.

  1. Unplug the unit and remove the water tank.
  2. Lift out the old wick filter from the base slot.
  3. Insert the new filter (Honeywell Part #HUL900FILTER). Ensure it is fully seated and straight.
  4. Reassemble the tank and base. The new filter must be saturated with water before operation.
  5. Run the unit for 15 minutes to fully wet the new filter.

Note: Using the humidifier without a filter or with a clogged filter can reduce performance and damage the unit.

Care & Storage

When not in use for an extended period, prepare the unit for storage.

  1. Unplug the unit and empty all water from the tank and base.
  2. Remove and discard the used wick filter.
  3. Clean all parts thoroughly as described in the Maintenance section and allow to dry completely.
  4. Store the unit in its original box or a clean, dry place.
  5. Do not store with a filter installed. Install a new filter at the start of the next season.

CAUTION! Never store with water inside. This can lead to mold, mildew, and damage.

Regulatory Information

FCC Compliance: This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Honeywell International Inc. Honeywell and Reflection are trademarks of Honeywell International Inc. For support, visit www.honeywellhumidifiers.com or contact Honeywell Customer Care at 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not power onNo power / Loose plugEnsure unit is plugged in securely. Check outlet with another device.
No mist outputEmpty tank / Clogged filterRefill water tank. Replace the wick filter if old or clogged.
Weak mist outputLow fan speed / Dirty filterIncrease fan speed. Clean or replace the wick filter.
Water leakageTank cap not tight / Cracked tankEnsure tank cap is securely tightened. Inspect tank for cracks.
Unusual noiseDry filter / Loose partsEnsure filter is wet. Check that tank is seated properly on base.
Display not workingPower issueUnplug and replug the unit. If problem persists, contact support.
Bad odor from mistDirty tank or filterClean the tank and base thoroughly. Replace the wick filter.

Reset: Unplug the unit for 60 seconds, then plug back in to reset the electronic controls.

Service: For repairs, contact authorized service center. Do not attempt to disassemble the unit.

Support: 1-800-332-1110; www.honeywellhumidifiers.com