The Honeywell Humidifier TrueEASE HE150 is a whole-home bypass humidifier designed for forced-air heating systems. It features an automatic digital humidistat, easy-access water panel, dual fan speeds, and a capacity to humidify homes up to 3,200 square feet. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Digital Humidistat Control, Bypass Damper, Water Panel (Evaporative Pad), Drain Hose, Dual-Speed Fan, Mounting Bracket.
| Feature | Description |
|---|---|
| Digital Humidistat | Automatic humidity control with LCD display |
| Bypass Damper | Regulates airflow from furnace plenum |
| Water Panel | Evaporative pad for moisture absorption |
| Drain Hose | Removes excess water to drain |
| Dual-Speed Fan | High/Low settings for optimal humidity output |
| Mounting Bracket | For secure installation on ductwork |
| Water Inlet Valve | Connects to home water supply (1/4" tubing) |
| Control Knob | Manual ON/OFF and fan speed selection |
| Indicator Lights | Power, Fan Speed, and Service alerts |
| Auto Shut-Off | Stops operation when desired humidity is reached |
Unpack and inspect contents. Ensure all parts are present.
WARNING! Installation should be performed by a qualified HVAC technician. Ensure power is OFF during installation.
After installation, power on humidifier; follow initial setup steps.
CAUTION! Do not set humidity too high to prevent condensation on windows.
Access controls via digital humidistat panel. Front Panel: Power Button, Fan Speed (High/Low), Humidity Setpoint (+/-), Display.
Humidistat Functions: Set desired humidity (20-60%), view current humidity, outdoor temperature display, fan speed indicator, service reminder.
Operation Modes: Automatic (adjusts based on outdoor temp), Manual (constant output). Settings: Service interval reminder (default 1 season), Fahrenheit/Celsius display, backlight timeout.
Bypass Installation: Requires connection to warm air supply and return air ducts.
Tip: Ensure proper slope on drain hose to prevent water accumulation.
Automatic operation with digital humidistat.
WARNING! Do not operate without water panel installed. Ensure drain is clear.
Regular maintenance ensures optimal performance and longevity.
Turn off power and water supply before cleaning.
CAUTION! Never use harsh chemicals or abrasives. Do not operate without water panel.
UL Listed. CSA Certified. FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-468-1502. Five-year limited warranty on humidifier; one-year warranty on water panel.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No humidity output | Power/water supply | Check power connection; ensure water valve is open; verify furnace is running. |
| Water leaking | Drain clog/connections | Clear drain hose; check water line connections; ensure proper installation slope. |
| Low humidity | Dirty water panel | Replace water panel; check fan operation; verify humidistat setting. |
| Fan not running | Power/obstruction | Check power supply; ensure fan blades rotate freely; reset if equipped. |
| Display blank | Power issue | Verify 120V power; check wiring connections; replace fuse if applicable. |
| Mineral buildup | Hard water | Clean with vinegar solution; consider water softener; replace panel more frequently. |
Reset: Turn power OFF for 30 seconds, then ON to reset control board.
Service: 1-800-468-1502; www.honeywellhome.com