The Honeywell Humidifier ULTRA COMFORT is a high-performance humidification system designed to add moisture to dry indoor air, providing relief from dry air discomforts such as dry skin, irritated sinuses, and static electricity. It features adjustable humidity control, a large-capacity water tank, wicking filter technology, quiet operation, and an easy-to-clean design. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Power 7. Operating the Humidifier 8. Maintenance & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Large-capacity water tank, Wicking Filter, Humidistat Control Dial, Power Switch, Mist Output Nozzle, Water Level Indicator, and Carry Handle.

FeatureDescription
Adjustable HumidistatDial control to set desired humidity level
Large Water TankHigh-capacity tank for extended operation
Wicking FilterAbsorbs water and helps remove impurities
Quiet OperationDesigned for low-noise performance
Power SwitchOn/Off control with indicator light
Mist Output NozzleAdjustable direction for mist dispersion
Water Level IndicatorShows remaining water in tank
Carry HandleFor easy transport and tank refilling
Easy-Clean DesignRemovable parts for simple maintenance
Auto Shut-OffTurns off when tank is empty or removed

Installation

Unpack and inspect all contents. Place on a flat, stable, and level surface away from direct sunlight and heat sources.

  1. Remove all packaging materials from the humidifier and tank.
  2. Install the wicking filter: Remove from packaging and insert into the filter slot in the base unit.
  3. Fill the water tank: Carry tank to sink, remove cap, fill with cool tap water, replace cap securely.
  4. Place tank on base: Align tank with base unit and set it down firmly.
  5. Position the humidifier: Ensure at least 6 inches of clearance on all sides for proper air flow.

WARNING! Do not operate without water. Do not block mist outlet. Use on a water-resistant surface.

First-Time Setup

After installation, prepare the humidifier for initial use.

  1. Ensure the humidifier is unplugged from power outlet.
  2. Fill the water tank completely as described in Installation.
  3. Place tank on base and allow a few minutes for the wicking filter to absorb water.
  4. Plug the power cord into a standard 120V AC electrical outlet.
  5. Turn the Power Switch to ON. The indicator light will illuminate.
  6. Adjust the Humidistat Control Dial to your desired humidity level (e.g., 40-50% relative humidity).
  7. Adjust the Mist Output Nozzle to direct mist away from walls, furniture, and electronics.

CAUTION! Use only cool tap water. Do not use hot water, additives, or essential oils unless specified.

Specifications

Controls and Settings

Front Panel Controls: Power Switch (On/Off with light), Humidistat Control Dial (Low to High settings).

Operation: Turn Power Switch ON. Adjust Humidistat Dial clockwise to increase humidity output (HIGH) or counterclockwise for lower output (LOW). The unit will run until the desired room humidity is reached or the tank is empty.

Indicator: Power light indicates unit is on. No separate low-water light; monitor Water Level Indicator visually.

Mist Nozzle: Manually rotate to direct mist flow.

Connecting to Power

Use only a 120V AC outlet. Ensure hands are dry.

  1. Place humidifier in desired location.
  2. Plug power cord directly into wall outlet. Do not use an extension cord.
  3. Ensure cord is not pinched or under the unit.

Tip: For safety, plug into a GFCI outlet in areas near water sources.

Operating the Humidifier

Daily operation steps for optimal performance.

  1. Check water level: Use the Water Level Indicator; refill when low.
  2. To refill: Turn Power Switch OFF. Lift tank off base, carry to sink, remove cap, fill with cool tap water, replace cap, return tank to base.
  3. Adjust settings: Use Humidistat Dial to increase or decrease mist output as needed for comfort.
  4. Direct mist: Adjust nozzle to ensure even distribution in room.
  5. When not in use: Turn Power Switch OFF, unplug unit, empty any remaining water from tank and base.

WARNING! Never move the unit while it is operating or full of water. Always turn off and unplug before servicing.

Maintenance & Cleaning

Regular cleaning prevents mold and mineral buildup. Clean every 1-2 weeks during use.

  1. Unplug the humidifier and remove water tank.
  2. Empty any remaining water from base.
  3. Clean tank: Rinse with clean water. For deposits, use mild detergent and soft brush. Rinse thoroughly.
  4. Clean base: Wipe interior with damp cloth. Use a mixture of white vinegar and water (1:1) to descale if needed. Rinse well.
  5. Clean wicking filter: Rinse under cool water if dirty. Replace filter every 1-2 months or as needed (Model FILTER-UC1).
  6. Dry all parts completely before reassembly.

CAUTION! Do not immerse base unit in water. Do not use harsh chemicals, abrasives, or bleach.

Regulatory Information

This humidifier complies with relevant U.S. safety standards. Copyright © Honeywell International Inc. Honeywell and ULTRA COMFORT are trademarks of Honeywell International Inc. For support, visit www.honeywellhome.com or contact Honeywell Customer Care at 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
No mist outputEmpty tank / Power offFill water tank; ensure unit is plugged in and Power Switch is ON.
Low mist outputClogged filter / Low settingClean or replace wicking filter; adjust Humidistat to higher setting.
Water leakageLoose cap / OverfilledEnsure tank cap is tight; do not overfill tank; check for cracks.
Unusual noiseMineral buildup / Loose partsClean base and tank; ensure tank is seated properly on base.
Bad odorDirty filter / Stagnant waterReplace wicking filter; clean tank and base thoroughly; use fresh water daily.
Power light offNo power / Faulty outletCheck outlet; ensure cord is plugged in securely; try another outlet.

Reset: Unplug unit for 5 minutes, then restart.

Service: 1-800-332-1110; www.honeywellhome.com

Honeywell Humidifier ULTRA COMFORT Manual © - All Rights Reserved 2025